Some of the common sense of the UV integrator
Date:2013/3/1 15:22:06
UV energy of questions and answers, based on many years of practical experience, to answer your questions related issues than Branch speed.
1 What is the UV energy meter?
A: UV energy meter, also known as the UV joulemeter, English name: uv-integrator A on the UV light source device used to accumulate heat value of the instrument.

2 units of UV energy meter is it?
A: UV energy meter units: MJ/cm2 generation of products for a few years in the United States EIT used J/cm2 do units, but now almost market with MJ/CM2 do UV energy meter units.

3, commonly used UV energy meter brand?
A: KUHNAST, UV-DESIGN, BIKESU, BELTRON, ORC, USHIO, HAMAMATSU, OPAS, RAPITECH, RUNWING, EIT, etc..

4, the most common market UV energy meter Model?
Answer: UV14, UV140, UV150, UV1400, UV150 +, UV160, UV-351, the EIT PowerPuck II UVICURE PLUS II, the UV-365A.

UV energy meter commonly spectrum is which?
A: According to the U.S. is divided into four UV spectral bands :320-390nm (UVA), 280-320nm (UVB), 250-260nm (UVC), 395-445nm (UVV), although this is not an international standard, but the countries the difference was not large.

6, UV energy meter battery can be long in the end?
A: German battery lithium battery, usually said about 10,000 hours, the actual use of the case did not go to trial before, but some customers to buy a German UV-INT150 energy after a period of five years to change the battery, we can see that this battery more durable because of the cost and technical reasons, but some manufacturers did not use lithium-powered, but household VII AAA batteries, to facilitate the replacement, but not durable.

7, What is the UV energy meter standard?
A: Actually, no industry standards and the national standards and the UV energy meter during operation is usually based on a single instrument to measure as standard, this standard can function calibration to increase or low instrument count speed therefore recommended two simultaneously adjust to the same standard, smaller adjustment potentiometer clockwise data, contrary becomes larger, but my recommendation would be sent to a professional sales and maintenance company to repair when you have two UV energy in the same production line.

8, UV150 and UV140 energy What is the difference?
A:
Dimensions: UV150 a diameter of 90mm, the UV140 diameter 140mm,
Weight: UV150 net weight of approximately 150g UV140 weight about 450 g
Sensor: UV150 apertures sensors, the temperature is only about 70 degrees, UV140 sensor temperature of 120 degrees for 20 seconds.
Price: imported 150 energy meter generally only 140 energy meter half.

EIT energy meter single-channel and four-channel 9 What is the difference?
A: single-channel UV instrument generally refers to the measured spectral range sensors can be installed only within the four-channel simultaneous measurement of UVA, UVB, UVC, UVV four different UV spectrum sensor, the equivalent of four single channel the energy meter together to work, but in terms of price, four-channel energy meter is generally single channel about three times the price, if you are not particularly cured production process requirements, it is recommended that you can pay channel.

10 Why use UV curing production?
A:
A, from the point of view of environmental protection can reduce the waste of resources, there will not be a large number of volatile chemical agent, causing environmental pollution.
B, greatly reducing the time of production processes, and improve production efficiency.
C, small equipment footprint, reducing station to reduce the operating costs of the plant.
D, easy to control quality, can significantly improve the yield of production.

11, the German production of UV-INT150, UV-INT140 how to function calibration?
A: cover two types of instruments in a calibration hole, find a small screwdriver to turn the potentiometer inside you can adjust the count rate of the instrument,
 
Generally clockwise smaller, on the contrary the data increase, based on the fold change, so tune the time to be careful, it is recommended to the professional company to do the the functional calibration, so that it can ensure that no damage to the instrument.

12 UV-INT159-type UV energy meter?
A: To be determined UV-INT159-type UV energy meter is made in China, Germany has never been out of this model, this can go to the official website in Germany.

Based on my years of work experience for reference learning with, Thank you for your support!